Load Cells

  

LC-5206


General purpose load cells ideally suited for platform and tank scale weighing

¡@

Features    

- Constant moment beam and shear beam construction

- Designed to resist overload damage

- Moisture protected

- Tension and compression loading

 

Specification

Rated capacities .............................300kgf, 500kgf, 1tf, 2tf
Rated output ....................................2mV/V¡Ó0.2%
Maximum safe overload ................200% of rated capacity
Combined error ..............................¡Ó 0.02% of rated output
Creep ................................................¡Ó0.1% of rated output/hour
Zero balance ...................................¡Ó 1% of rated output
Compensated
temperature range......................... -10¢XC~+60¢XC/+14¢XF~+140¢XF
Recommended
excitation voltage ............................12V
Maximum
excitation voltage ...........................15V
Input terminal resistance .............Approximately 400£[
Output terminal resistance ..........350£[¡Ó 3.5£[
Insulation resistance ....................Greater than 5000M£[ at DC50V
Temperature effect
Zero ..................................................0.007% of rated output/¢XC
Span .................................................0.002% of rated output/¢XCTyp.
Cable length 3m/118 inches (1&2t-5m/197 inches)

¡@