LCB01/02/06
Explosion proof single point load cells ideal for hazardous environment applications
Capacity
|
Model No.
|
30kgf
|
LCB01K030E
|
60kgf
|
LCB01K060E
|
150kgf
|
LCB02K150E
|
300kgf
|
LCB06K300E
|
600kgf
|
LCB06K600E
|
Features
Adjusted for four corners
Tension and compression loading
Maximum pan sizes are 400¡Ñ400mm(LCB01),400¡Ñ600mm(LCB02)and 600¡Ñ700mm(LCB06)
Specification
Rated capacities ....................................30kgf, 60kgf, 150kgf,300kgf,600kgf
Rated output ...........................................0.3mV/V¡Ó10%(LCB01/02) 0.55mV/V¡Ó10%(LCB06)
Maximum safe overload .......................150% of R.C.
Combined error .....................................0.03% of R.O.
Zero balance......................................... 20¡Ó5% of R.O.
Compensated
temperature range ...............................-10¢XC~40¢XC
Recommended excitation voltage .....12V
Maximum excitation voltage ................15V
Input terminal resistance ....................410 ¡Ó 20£[
Output terminal resistance .................350 ¡Ó 5£[
Insulation resistance ..........................5000M£[ at DC50V
Temperature effect
Zero ........................................................0.05% of R.O./10¢XC
Span ......................................................0.03% of Load /10¢XCTyp.
Cable length ........................................ø 7/6m
Dust & Waterproof IP54
Maximum pan size 400¡Ñ400mm(LCB01) 400¡Ñ600mm(LCB02) 400¡Ñ700mm(LCB06)
¡@
¡@