Load Cells

LCB01/02/06

 

Explosion proof single point load cells ideal for hazardous environment applications

Capacity
Model No.
30kgf
LCB01K030E
60kgf
LCB01K060E
150kgf
LCB02K150E
300kgf
LCB06K300E
600kgf
LCB06K600E

Features
Adjusted for four corners
Tension and compression loading
Maximum pan sizes are 400¡Ñ400mm(LCB01),400¡Ñ600mm(LCB02)and 600¡Ñ700mm(LCB06)


Specification

Rated capacities ....................................30kgf, 60kgf, 150kgf,300kgf,600kgf
Rated output ...........................................0.3mV/V¡Ó10%(LCB01/02) 0.55mV/V¡Ó10%(LCB06)
Maximum safe overload .......................150% of R.C.
Combined error .....................................0.03% of R.O.
Zero balance......................................... 20¡Ó5% of R.O.
Compensated
temperature range ...............................-10¢XC~40¢XC
Recommended excitation voltage .....12V
Maximum excitation voltage ................15V
Input terminal resistance ....................410 ¡Ó 20£[
Output terminal resistance .................350 ¡Ó 5£[
Insulation resistance ..........................5000M£[ at DC50V
Temperature effect
Zero ........................................................0.05% of R.O./10¢XC
Span ......................................................0.03% of Load /10¢XCTyp.
Cable length ........................................ø 7/6m
Dust & Waterproof IP54